Interested
in the EPTC-M ?
General introduction
AC hipot testing is the effective and direct way to test insulation strength for electric equipment. It checks dangerous flaws and make sure electric equipment continuous working. It typically used to test insulation strength for all kinds of electrical equipment, components like capacitors, insulation materials.
The controller should be equipped with AC/DC HV source to boost. There are three types of testing transformers for optional:
1. Oil-immersed: large capacity, cheap, convenient maintenance, mainstream products.
2. Dry type: light weight, light volume, can run backward, price expensive.
3. Gas inflatable type: interrupter resistance, and light weight.
4. Series type high voltage testing transformer: small volume, low voltage, light weight, easy to transport and install.

General Information:
EPTC-M Series AC/DC Hipot Test Set is suitable for hipot dielectric withstand voltage testing on various power electric products, units, insulating materials. The controller should be equipped with AC/DC HV source to boost. There are three types of testing transformers for optional.

Features
  • ◆ Manual controlling.
  • ◆ Oil-immersed, dry, SF6 gas type transformer is selectable according to user’s requirements.
  • ◆ High anti interference ability.
  • ◆ High voltage (HV) voltage, Low voltage (LV) current, time, three channels testing ways.
  • ◆ Real time monitoring HV voltage, LV current.
  • ◆ Full protection functions: over-current, zero-starting sound light alarm, power switch protection.
  • ◆ New type time rely, wider time range (1S ~ 99H).
  • ◆ New type current rely, more precise, more reliable.
  • ◆ 5kVA and above Testing Transformer with movable iron wheel. Light weight, small size, easy to move, superior performance.
  • ◆ The control tester can be designed to box type, table type, or cabinet type according to user’s testing capacity:
  • 5kVAor below, Box type
  • 10kVAor above Table type
  • 50kVAor above Cabinet type.
  • ◆ Add rectifying installation to support AC/DC function.(option)

Specifications:
  • ◆ Input voltage: AC 220(380)V (customized)
  • ◆ LV output: AC 0-250(430)V
  • ◆ LV current: 0-5/10/15/50A (customized)
  • ◆ Output capacity: 0-3/5/10/15 kVA (customized)
  • ◆ HV output: 0-50/100/150/200 kV (customized)
  • ◆ HV current: 0-50/100/150/200/500/1000/2000mA (customized)
  • ◆ Timing range: 0-9999S
  • ◆ Working temperature: -20℃ to 50℃
  • ◆ Voltage precision: ≤1.5% ±1 digit (F.S)
  • ◆ Current precision: ≤1.5% ±1digit (F.S)

Main parameters of EPTC-M Control Unit:
Model Input Voltage
(V)
Capacity
(kVA)
Rated Output HV voltmeter
kV/V
Oversize
m3(L×W×H)
Voltage(V) Current(A)
EPTC-M05 220 0.5 200 2.5 50/100 20×30×20
EPTC-M15 220 1.5 200 7.5 50/100 26×36×24
EPTC-M3 220 3 200 15 50/100 26×42×24
EPTC-M5 220 5 200 25 50/100 60×45×37
EPTC-M6 220 6 200 30 50/100 53×40×60
EPTC-M10 220 10 200 50/25 (50/100)/100 53×40×65
EPTC-M15 380 15 400 37.5 (50/100/150)/100 53×40×70
EPTC-M20 380 20 400 50 (50/100/150)/100 53×43×84
EPTC-M25 380 25 400 62.5 (50/100/150)/100 53×45×90
EPTC-M30 380 30 400 67.5 (50/100/150)/100 65×55×115
EPTC-M40 380 40 400 100 (50/100/150)/100 70×60×115
EPTC-M50 380 50 400 125 (50/100/150)/100 70×60×115

Other accessories for option:
◆ AC/DC Digital Voltage Meter: 50,100,150,200kV
◆ Sphere Gap
◆ DC microammeter
◆ Discharge stick
◆ Water resistor
◆ HV filter capacitor: 0.01μF-0.1μF, 40-300kV
◆ Trolley
◆ Insulating support: 50,100,200,300kV
◆ Standard Oil cup: 400ml
◆ HV electroscope: 10, 35kV