Specifications | |
Time test: | 6 channels (12 channels is for option) Open(Close)time Open(Close)one phase no- synchronism Open(Close)phase to phase no-synchronism Close(Open)bounce time(bounce numbers) Test range:0.01ms~10000ms Accuracy:1ms~100ms: 0.5%±2digits >100ms: 1%±2digits |
Velocity test: | Open(Close)velocity Pointed periods of time(travel period or angle period)average speed Open(Close)max. speed. Range: 1mm Sensor:0.01~25.00m/s, 0.1mm sensor: 0.001~2.50m/s 0.5°angle sensor: 0.01~25.00m/s Universal sensor: 0.01~25.00m/s |
Travel test: | Active contactor travel Contactor travel (open distance) Overshoot travel or bounce travel (over travel) |
Sensor measuring range: | Linear position sensor 50mm, Resolution: 0.1mm, travel 0.1~50mm. Linear position sensor 300mm, Resolution: 0.1mm, travel 10~300mm Linear position sensor 500mm, Resolution: 1mm, travel 10~500mm 360 sensor:360о,resolution:0.5о ,travel 5mm~999mm. Universal sensor: resolution: 0.1mm, travel 5mm~999mm. |
Current measuring: | The displayed current is max. open(close) coil current value. |
AC source: | AC 220V ± 20%;50Hz ± 2% (Can be customized) |
DC source: | Output voltage:15~265V continuous adjustment,output current:≤ 15A(short time) |
Control unit oversize: | 360×250×140mm |
Working temperature: | -20℃~+50℃ |
RH: | ≤90% |