General Information:
Transformer Induction Withstand Voltage Test Set DVDF Test System mainly designed for transformer induced withstand voltage test and partial discharge test.


DVDF ControlTable:

ü 3 phase 4lines

ü Controlled by push button.

ü Designed for generator set controlling.

ü High anti interference ability

ü Full protection functions: over-current, over-voltage, zero-starting light alarm.

ü During testing process, press exit button to quit any tests. Press Emergency button ifany abnormal happened.

ü Digital voltage/current meter, precision 1.5 degree.

ü Power source: 3 phase


The system is consisted by below units:

ü Generator Motor Set: EPYZR 1set

ü Generator Motor Set Controlling Table: EP-DVDF 1set


Motor Generator Set Main Specifications:

Power

kVA

Output Frequency

Hz

Operating CurrentA

Exciting VoltageV

Exciting CurrentA

Rated Output CurrentA

Rated Output VoltageV

30

150

9-14

140-185

15-18

15

800

30

150

9-14

140-185

11-25

9.5

1400

30

100

9-14

140-185

11-18

16

800

40

150

9-11

130-140

18-19

20.1

800

50

150

14-19

130-185

22-30

24.5

800

50

150

14-19

130-185

22-35

32

1400

50

100

14-19

140-185

22-30

16

800

60

150

19-24

100-150

11-18

32.5

800

60

150

19-24

170-220

28-38

22

1400

60

100

19-24

170-220

11-18

33

800

75

150

17-26

210-250

35-42

41

800

75

150

17-26

240-300

40-48

24

1400


More details on transformer inductive testing machine, please contact EP Hipot Electric: tech@ephipot.com. We can customize correctly designed products for you.